Additional Optical Tests (Optional) - Alcatel-Lucent 1665 Installation Manual

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Installation tests
............................................................................................................................................................................................................................................................
LED test procedure
........................................................................................................................................................................................................................
1
Select Fault > Test > LED...
........................................................................................................................................................................................................................
2
Choose shelf (Alcatel-Lucent 1665 DMX).
........................................................................................................................................................................................................................
3
Click Select.
........................................................................................................................................................................................................................
4
Choose Number of Iterations: 1.
........................................................................................................................................................................................................................
5
Click OK.
Result:
seconds, and then the proper LEDs will light to indicate the current status of the shelf.
........................................................................................................................................................................................................................
6
Check off the appropriate box in
E
O
N D
........................................................................................................................................................

Additional optical tests (optional)

Low-speed optical testing
The following procedure is provided for installers wishing to further test the low-speed
optical packs using an optical test set. Perform the following steps for all Alcatel-Lucent
1665 DMX shelf Function unit or Growth slots. DCC will be disabled in order to prevent
DCC alarms from being generated due to the optical loopback.
To test this procedure an optical test set is required as well as a 1x2 optical splitter.
............................................................................................................................................................................................................................................................
6 - 5 2
All LEDs on the shelf should light for 10 seconds, then extinguish for 10
S
F
T E P S
NOTICE
Laser Safety
When connecting fiber loops between the IN and OUT ports on optical circuit
packs, always connect to the IN port first and then the OUT port. This will
prevent any optical radiation from being present at the fiber end.
Table I-3, Installation acceptance
Additional optical tests (optional)
checklist.
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010