WDMX setup and testing: integration procedures
........................................................................................................................................................................
................................................................................................................................................
14
Perform end-to-end testing. Follow the end to end testing procedures determined by the
input test signal. If the test signal is the Alcatel-Lucent 1665 DMX as part of a ring,
proceed to
locate the appropriate procedure.
................................................................................................................................................
15
Check off the appropriate box in
E
O
N D
........................................................................................................................................................

Turn up and test the LNW705 muxponder

Description
The following procedure is a simple method of testing end to end continuity of the
LNW705 Muxponder circuit. The test requires that a LNW705 is installed in two nodes
and that there is fiber continuity between the two LNW705s. The fiber path could be a
direct fiber connection, through a passive optics device, a LNW785 or through a DWDM
like the Alcatel-Lucent 1695 EON system. In any case, the LNW705 link must be
established. Once the end-to-end link has been established, an OC-3/OC-12/OC-48 test set
and PTMs will be used to perform the end to end test.
Steps
This procedure provides the steps needed to equip and test the Alcatel-Lucent 1665 DMX
with an LNW705. The steps include installing and equipping the LNW705 with the 10G
and low speed PTMs, along with all the necessary provisioning.
................................................................................................................................................
1
Install the LNW705 into the Alcatel-Lucent 1665 DMX shelf by opening both faceplate
latches and seating in the slot while closing the latches.
Note:
are not equipped with VLF mains (LNW59, LNW82, LNW504), then the circuit packs
in a Function/Growth slot must be the same type.
................................................................................................................................................
2
Install the appropriate 10G PTM
........................................................................................................................................................................
9 - 6
Chapter 8, "OC-3/12/48 ring setup and testing: integration procedures"
S
F
T E P S
The LNW705 can be installed in any Function/Growth slot. If the Main slots
Table I-3, Installation acceptance
"Channel/port assignments" (p. 9-17)
Turn up and test the LNW705 muxponder
checklist.
into Port 9.