Alcatel-Lucent 1665 Installation Manual page 149

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Cable and fiber installation
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
3
Cut the miscellaneous (environmental) discrete telemetry cable to the desired length at the
telemetry panel.
........................................................................................................................................................................................................................
4
Wire-wrap the loose end of the miscellaneous (environmental) discrete telemetry cable to
the wire-wrap terminal strip, making connections per
(environmental) discrete telemetry connections" (p.
Note:
connected to the Alcatel-Lucent 1665 DMX high-capacity shelf by two leads (wires).
For each input, one lead should be connected to input-common and the other lead
should be connected to the appropriate alarm indication.
For each output, one lead should be connected to output-common and the other lead
should be connected to the appropriate alarm indication.
........................................................................................................................................................................................................................
5
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
Table 3-24 Miscellaneous discrete cable assemblies
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
Each miscellaneous (environmental) discrete telemetry designation is
S
F
T E P S
Description
Miscellaneous
discrete cable
Miscellaneous (environmental) discrete telemetry cable
Table 3-25, "Miscellaneous
3-60).
Table I-3, Installation acceptance
Cable
Cable
length
assembly #
(feet)
109321794
15
109321802
30
848839569
50
848839577
100
848839585
150
848839593
250
848839601
350
installation
checklist.
Backplane
connections
J11
3 - 5 9

Advertisement

Table of Contents
loading