Installation tests
............................................................................................................................................................................................................................................................
DS1 path switching test (manual)
Note:
this procedure should be performed on each Function unit Slot pair.
........................................................................................................................................................................................................................
1
Select Fault > Protection Switch...
........................................................................................................................................................................................................................
2
Under Path Protection, click on Path m1-1-1-1.
........................................................................................................................................................................................................................
3
Click Select.
........................................................................................................................................................................................................................
4
At the Switch Type: pull-down, select Manual.
........................................................................................................................................................................................................................
5
Click Apply.
Result:
the active path, the switch is from m2 to m1).
The Switch Request State: indicates Manual Switch.
........................................................................................................................................................................................................................
6
At the Switch Type: pull-down, select Clear.
........................................................................................................................................................................................................................
7
Click Apply.
........................................................................................................................................................................................................................
8
Repeat
........................................................................................................................................................................................................................
9
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
It is not mandatory to perform this test on each vt cross-connection, however
The Active Path: indicates a change from m1 to m2 (or if m2 was originally
Step 1
through
Step 7
S
F
T E P S
to verify a switch back to the original ring.
Table I-3, Installation acceptance checklist
DS1 protection switching