Shutting Down The System To Add Or Replace Hardware - Nortel Contivity 600 Installing

Hardware options for the contivity secure ip services gateway
Hide thumbs Also See for Contivity 600:
Table of Contents

Advertisement

54 Chapter 4 Contivity 1740 option installation

Shutting down the system to add or replace hardware

To install or replace an option card or a DIMM, you must first shut down the
Contivity 1740 and unplug it.
To shut down the Contivity 1740:
1
Use the Web GUI or the command line interface to shut down the gateway.
2
Wait for the system to shut down.
3
Disconnect the power cord from the power outlet and then disconnect the cord
from the Contivity 1740.
The power receptacle is located on the rear of the Contivity 1740.
302283-K Rev 00
Caution: Shut down the Contivity 1740 as described in this section
before you attempt to add or replace an option card or DIMM.
Web GUI: Choose Admin > Shutdown. Select the option to power off the
gateway after shutdown.
Command line interface: Use the
system. For example, enter
"Upgrade hardware"
For the complete syntax of the
the Contivity Secure IP Services Gateway Command Line Interface.
Danger: Make sure to turn off the Contivity 1740 and unplug the power
cord before you attempt to remove or install an option card or DIMM.
command to shut down the
reload
reload power-off disable-logins
command, see the Reference for
reload