40 Chapter 3 Contivity 1700 and 1600 option installation
Shutting down the system to add or replace hardware
To install or replace an option card or a DIMM, you must first shut down the
Contivity 1700 or Contivity 1600 and unplug it.
To shut down the Contivity 1600 or 1700:
1
Use the Web GUI or the command line interface to shut down the gateway.
•
•
2
Wait for the system to shut down.
3
Disconnect the power cord from the power outlet and then disconnect the cord
from the Contivity 1700 or 1600.
The power receptacle is located on the rear of the gateway.
302283-K Rev 00
Caution: Shut down the gateway as described in this section before you
attempt to add or replace an option card or DIMM.
Web GUI: Choose Admin > Shutdown. Select the option to power off the
gateway after shutdown.
Command line interface: Use the
system. For example, enter
"Upgrade hardware"
For the complete syntax of the
the Contivity Secure IP Services Gateway Command Line Interface.
Danger: Make sure to turn off the gateway and unplug the power cord
before you attempt to remove or install an option card or DIMM.
command to shut down the
reload
reload power-off disable-logins
command, see the Reference for
reload