The options are as follows:
Gap + I-Mark
Adjusts both the Gap sensor and I-mark sensor.
Gap
Adjusts the Gap sensor.
I-Mark
Adjusts the I-mark sensor.
The procedure to auto-calibrate the media sensor is as follows:
1. Open the top cover.
2. Load the media.
Remove the label from the media and place the liner above the gap sensor position.
3. Close the top cover.
4. Select the type of sensor to adjust, and then press the
5. When the confirmation screen appears, press the
If message indicating adjustment failed, load the media correctly and try again.
6. Press the
7. Reload the media.
8. Confirm the results of adjusting the media sensor.
Display the Offline screen, press the
correctly.
If the media is not fed correctly after executing [Auto-calibration], contact your SATO
reseller or technical support.
[GAP Levels]
Manually set the Gap sensor level.
The setting procedure is as follows:
First, adjust the "Low" level (voltage) of the Gap sensor.
1. Remove the label from the liner.
button (
).
button (START).
button (
button (FEED), and then confirm that the media is fed
148
[Advanced]
) to start adjusting the sensors.