Figure 41: Securing the Power Cord on the MAG-RK1U4 Mounting Tray

Repeat Steps 2 through 8 for each MAG2600 you want to mount in this tray.
9.
Replace the front panel and tighten the thumbscrews using a number-1 Phillips
10.
screwdriver.
Gently squeeze the powerclip holder and insert the tips into the holes located on the
11.
back of the mounting tray. See
Gently lift the powerclip holder and plug the AC adapter into the power connector
12.
located on the back of the MAG2600 power supply.
To install the MAG-RK1U4 mounting tray in a rack:
Have one person grasp the sides of the device, lift it, and position it in the rack.
1.
Align the bottom hole in each mounting bracket with a hole in each rack rail, making
2.
sure the mounting rack is level.
Have a second person install a mounting screw into each of the two aligned holes.
3.
Use a number-3 Phillips screwdriver to tighten the screws.
Install the second screw in each mounting bracket.
4.
Verify that the mounting screws on one side of the rack are aligned with the mounting
5.
screws on the opposite side and that the device is level.
Installing the Junos Pulse Gateway MAG2600 on a Desk on page 67
Chapter 9: Installing the Junos Pulse Gateway
Figure 41 on page
73.