Installing an AC Power Supply in the MAG6610 and MAG6611

Related
Documentation
Copyright © 2014, Juniper Networks, Inc.
Installing the Integrated Access Service Modules Overview on page 49
Installing a Fan Assembly in the MAG6610 and MAG6611 on page 48
Installing a Hard Drive in the MAG6610 or MAG6611 on page 48
Before you install an AC power supply in the Junos Pulse Gateway, make sure that you
understand how to prevent ESD damage.
NOTE:
Each power supply must be connected to a dedicated power source
outlet.
The power supply in the Junos Pulse Gateway MAG6611 is a hot-removable and
hot-insertable field-replaceable unit (FRU). If you have two power supplies already
installed, you can remove and replace one of the power supplies without powering off
the Junos Pulse Gateway.
The AC power supply is neither a hot-removable nor a hot-insertable FRU on the
MAG6610. You must power off the MAG6610 before replacing the AC power supply. The
MAG6610 is shipped with the power supply pre-installed. Follow these instructions only
if you need to replace the power supply on the MAG6610.
To install a power supply in the Junos Pulse Gateway:
Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and
1.
connect the strap to the ESD point on the chassis.
If the power supply slot has a cover panel on it, pull the handle of the cover panel
2.
outward and remove the panel. Save the cover panel for later use.
Taking care not to touch power supply pins, leads, or solder connections, remove the
3.
power supply from the bag.
Using both hands, place the power supply in the power supply slot on the rear panel
4.
of the chassis, and slide it in until it is fully seated. You will hear a distinct click when
the power supply is fully seated in the chassis. See

Figure 16: MAG6611 With a Single AC Power Supply

Connecting Power to an AC-Powered Junos Pulse Gateway on page 76
Removing the MAG6610 and MAG6611 AC Power Supply on page 89
Chapter 8: Installing Junos Pulse Gateway Components
Figure 16 on page
47.