Installing a MAG-CM060 Chassis Management Card

50
Installing the MAG-SM161 Kit on page 44
Installing the MAG-SM360 Kit on page 43
Installing the MAG-SM361 Kit on page 45
Configuring the MAG2600, MAG-SM160 and MAG-SM360 Service Module on page 83
Monitoring the Junos Pulse Gateway Components Using LEDs on page 99
The MAG-CM060 chassis management card (CMC) can be installed in an even-numbered
slot (for example, slot 0 or slot 2) in an installed service module.
To install a MAG-CM060 in a MAG6610 or MAG6611:
Power off the device by pressing and holding the power switch located on the back
1.
of the Junos Pulse Gateway chassis for 5 to 10 seconds.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
2.
the strap to the grounding point on the back of the device.
Gently pry the blank faceplate from the chassis using your fingers or a flat-blade
3.
screwdriver.
Using a Phillips screwdriver, remove the two screws retaining the metal faceplate,
4.
and then remove the metal faceplate.
Grasp the faceplate of the MAG-CM060, and align the notches in the connector at
5.
the rear of the MAG-CM060 with the notches in the service module.
Slide in the MAG-CM060 until it lodges firmly in the chassis.
6.
Tighten the thumbscrews until they are finger tight.
7.
Connect the MAG-CM060 to a management console before powering up the Junos Pulse
Gateway. Connect a serial cable to the port labeled CONSOLE on the MAG-CM060 front
panel, and connect the other end of the serial cable to the serial port on the management
device.
Copyright © 2014, Juniper Networks, Inc.