[:SENSe]:FUNCtion?
Description
Response
Examples
RESistance:RANGe
Description
Parameters
Examples
RESistance:RANGe?
Description
Response
Examples
90
= RV
= RESistance
= VOLTage
FUNC EPCCheck
Query the measurement function.
{RVOLtage | EPCCHECK | PEVOLTAGE | NEVOLTAGE | RV | RESISTANCE |
VOLTAGE}
FUNC?
EPCCHECK
Set the resistance measurement range.
<NRf (0 to 10)>
= [0, 3.0000E-03]
= (3.0000E-
03,3.0000E-02]
= (3.0000E-
02,3.0000E-01]
= (3.0000E-
01,3.0000E+00]
=
(3.0000E+00,1.0000E+01]
RES:RANG 3.0000E-03
Query the resistance measurement range.
{AUTO | 3.0000E-03 | 3.0000E-02 | 3.0000E-01 | 3.0000E+00 |
1.0000E+01}
RES:RANG?
3.0000E-03
Measurement function is ACR+DCV, READ? and
FETCh? return readings including ACR and
DCV.
Measurement function is ACR, READ? and
FETCh? return readings including ACR.
Measurement function is DCV, READ? and
FETCh? return readings including DCV.
The resistance measurement range is 3 mΩ.
The resistance measurement range is 30 mΩ.
The resistance measurement range is 300 mΩ.
The resistance measurement range is 3 Ω.
The resistance measurement range is 10 Ω.
Select the resistance measurement range for
measuring 3 mΩ.
The current resistance measurement range is
3 mΩ.