Repair Procedures - Daikin Perfera ARXM25A Service Manual

Table of Contents

Advertisement

4
|
Third party components
To check if the power supply is compliant with the regulations
To check the wiring between the outdoor unit and the indoor unit

4.1.2 Repair procedures

To adjust the power supply
Service manual
52
draft – 21/12/2023 13:09
6 Check the power supply to the unit, see
Does the unit receive power?
Yes
No
1 Check that the power source is in line with the requirements described in the
databook.
Is the power supply compliant with the
regulations?
Yes
No
1 Check that all wires are properly connected and that all connectors are fully
plugged‑in.
2 Check that no connectors or wires are damaged.
3 Check that the wiring corresponds with the wiring diagram, see
4
diagram" [
 70].
INFORMATION
Correct the wiring as needed.
Is the problem solved?
Yes
No
1 Make sure that the power source is in line with the requirements described in
the databook.
2 Adjust the power supply within 50 Hz ± 3%.
Is the problem solved?
Yes
No
"4.1.1 Checking
procedures" [
Action
Correct the wiring from the main power
supply terminal to the indoor unit
power supply terminal, see
"4.1.2 Repair
procedures" [
Adjust the power supply to the unit, see
"4.1.2 Repair
procedures" [
Action
Return to the troubleshooting of the
specific error and continue with the
next procedure.
Adjust the power supply, see
"4.1.2 Repair
procedures" [
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
RXM20~50A + ARXM25~50A + FTXM20~50A + ATXM20~50A + CTXM15A
4
 51].
4
 52].
4
 52].
4
 52].
"6.2  Wiring
Split Perfera ZETA R32
ESIE23-06 – 2023.12

Advertisement

Table of Contents
loading