Repair

Repair
Repair
Repair
To avoid electric shock, fire and explosion hazard,
and/or injury from moving parts hazard, turn off
equipment power and shut off power at the main
circuit breaker before repairing. Wear appropriate
protective equipment when in work area. Wait five
minutes before servicing.
Make sure wires are not pinched when re-installing
covers. Wires will be damaged and create an
electrical hazard and/or fire and explosion hazard
if pinched.
NOTE:
NOTE:
NOTE: Consult Graco Technical Assistance or your
Graco distributor for genuine replacement fasteners.
M8 x 30 socket-head cap screws of Class 12.9 steel
or better with a minimum yield strength of 1100 MPa
(160,000 psi) are acceptable alternatives.
12
Replace Output
Replace
Replace
Output Seal
Output
Seal Cartridge
1. Stop the pump at the bottom of its stroke. Shut
off and lock out power to the driver.
2. Follow the
Pressure Relief Procedure, page 8
3. Disconnect the pump lower from the driver, as
explained in your separate system manual.
4. Drain the oil from the driver. See
Change the Oil, page 9
5. Reinstall the oil drain plug. Torque to 18–23 ft-lb
(25–30 N•m).
6. Unscrew the output cartridge (19) from the driver.
See
Parts, page
22.
7. Install the new output cartridge. Torque to
175–200 ft-lb (240–280 N•m).
8. Fill with oil. See
Change the Oil, page 9
9. Reconnect the pump lower to the driver.
10. Turn on power and resume operation.