1. Connect one end of the cable to one of the management ports (labeled MGMT on the
ACX7100-32C router.
2. Connect the other end of the cable to the management PC (see
Figure 33: Connect an ACX7100-32C Router to a Network for Out-of-Band Management
Connect an ACX7100-32C Router to External Clocking and Timing
Devices
The ACX7100-32C router has four SMB connector ports that support 1-PPS and 10-MHz timing
devices.
NOTE: Ensure that you use a cable of 3 m or less in length for the 10-MHz and 1-PPS
connectors.
To connect the SMB to BNC coaxial cable to the external clocking input port:
1. Connect one end of the SMB to BNC coaxial cable to either the 1-PPS connector or the 10-MHz
connector on the router.
2. Connect the other end of the SMB to BNC coaxial cable to the 1-PPS or 10-MHz measurement
equipment.
Figure 33 on page
77).