Connect The Router To External Clocking And Timing Devices; Connect 1-Pps And 10-Mhz Timing Devices To The Router - Juniper MX204 Quick Start Manual

Universal routing platform
Hide thumbs Also See for MX204:
Table of Contents

Advertisement

Table 3: Console Port on the MX204 Router
Callout
14
(See
Figure 13 on page
13)

Connect the Router to External Clocking and Timing Devices

IN THIS SECTION

Connect 1-PPS and 10-MHz Timing Devices to the Router | 16

Connect a Time-of-Day Device to the Router | 17
Connect a BITS External Clocking Device to the Router | 17
Connect 1-PPS and 10-MHz Timing Devices to the Router
The router has four SubMiniature B (SMB) connectors that support 1-PPS and 10-MHz timing devices.
NOTE: Ensure that a cable of 3 m or less in length is used for the 10-MHz and 1-PPS connectors.
To connect the SMB coaxial cable to the external clocking input port:
1. Connect one end of the SMB coaxial cable to either the 1-PPS SMB connector or the 10-MHz SMB
connector on the router.
2. Connect the other end of the SMB coaxial cable to the 10-MHz or 1-PPS source network equipment.
NOTE: Ensure that the 10-MHz or 1-PPS source network equipment contains low voltage
complementary metal oxide semiconductor (LVCMOS) or is compatible with low-voltage
(3.3 V) transistor–transistor logic (LVTTL).
Label
CON
Description
Connect a laptop or console terminal to
configure the router.
16

Advertisement

Table of Contents
loading

Table of Contents