2: Mfx 1; 3: Mfx 2; 4: Meq (Master Eq) - Korg Triton-Rack Parameter Manual

Hide thumbs Also See for Triton-Rack:
Table of Contents

Advertisement

Signal (Chain Signal)
When chain is On, this parameter specifies how the stereo
output signal of the first master effect will be connected to
the input (mono) of the next master effect.
L/R Mix: The stereo output L/R of the first master effect will
be mixed before being input to the next master effect.
L Only, R Only: Only the left or right channel of the output
will be input to the next master effect.
Level (Chain Level)
Sets the send level from the first master effect to the next
master effect when chain is turned on.
7.3–1c: Master EQ Gain [dB]
Sets the gain for the three-band EQ located immediately
before the sound of the L/R bus is sent from the AUDIO
OUTPUT (MAIN OUT) L/MONO and R jacks. This is
linked with the various "Gain" parameters of Master EQ
(7.3–4).
Low
Mid
High
The cutoff frequency for "Low," "Mid" and "High" and the
"Q" of "Mid" can be adjusted in the MEQ page. These set-
tings are in "dB" units.
7.3–1d: UTILITY
"Write Program" (1.1–1d)
For details on how to select the desired utility function, refer
to "PROG 1.1–1d: UTILITY."
Copy Master Effect
This command lets you copy any desired effect settings from
Program, Combination, Multi or Sampling modes.
1 Select "Copy Master Effect" to access the dialog box.
2 In "From," select the copy source mode, bank, and num-
ber.
You can use the [BANK] and [A]–[H] keys to select the
bank.
3 Select the effect that you wish to copy. If you select MFX
1 or 2, "Rtn (Return)" (return level) will be copied at the
same time. If you select Master EQ," only the master EQ
settings will be copied. You can also copy from an insert
effect. If you check "All," all settings of the master effects
and master EQ will be copied.
If you copy from an insert effect the result may not be
identical, due to differences in routing and level set-
tings.
4 Select the copy destination master effect.
5 To execute the Copy Master Effect command, press the
[F8] ("OK") key. To cancel, press the [F7] ("Cancel") key.
30
[LR Mix, L Only, R Only]
[000...127]
[–18.0...+18.0]
[–18.0...+18.0]
[–18.0...+18.0]
Swap Master Effect
This command swaps (exchanges) the settings of MFX1 and
MFX2.
1 Select "Swap Master Effect" to access the dialog box.
2 To execute the Swap Master Effect command, press the
[F8] ("OK") key. To cancel, press the [F7] ("Cancel") key.
Select by Category
Selects master effects by category. ( p.2)
This command can be used when selecting "Master
Effect 1"–"Master Effect 2."
7.3–2: MFX 1
7.3–3: MFX 2
Indicates effect parameter settings for the MFX1 and 2
effects that were selected in the Setup page ( p.151).
( p.211 "D.mod")
7.3–2(3)a: UTILITY
"Write Program" (1.1–1d)
7.3–4: MEQ
(Master EQ)
The master EQ is a three-band stereo EQ. It is used to adjust
the overall tonality of the sound immediately before the L/R
bus is output to the AUDIO OUTPUT (MAIN OUT) L/
MONO and R jacks ( p.203).
7.3–4a: UTILITY
"Write Program" (1.1–1d)
7.3–2b
7.3–4a

Advertisement

Table of Contents
loading

Table of Contents