Effect 2 depth (IFX1–5 on/off) (CC#92) [Bn, 5C, vv]
Effect 4 depth (MFX1 on/off) (CC#94) [Bn, 5E, vv]
Effect 5 depth (MFX2 on/off) (CC#95) [Bn, 5F, vv]
Separately from the effect on/off settings in each mode,
GLOBAL 1.1:System, Basic page "FX SW" allows you to
turn off insert effects IFX1–5 and master effects MFX1 and
MFX2. If you check "IFX1–5 Off," "MFX1 Off" or "MFX2
Off," the corresponding message will be transmitted with
vv=0 [00]. If you uncheck these settings, the corresponding
message will be transmitted with vv=127 [7F]. If you check
these settings, the corresponding effect(s) will be turned off
as a group. If you uncheck these settings, the on/off settings
of each mode will be used. The same applies to reception.
(vv of 00 is off, and 01 or greater is the original setting.)
These messages are transmitted/received on the global
MIDI channel. ( p.28, 29 "ON/OFF" - "MIDI")
These messages are defined simply for use in adjusting
the effect levels, and may not have the same function on
another instrument connected to the TRITON-Rack.
Using various controllers for control
Knob modulation 1, 2, 3, 4 (CC#17, 19, 20, 21)
[Bn, 11, vv], [Bn, 13, vv], [Bn, 14, vv], [Bn, 15, vv]
If you assign the above CC# to the B-mode function of a
REALTIME CONTROLS [1]–[4] knob, and operate the corre-
sponding controller of the TRITON-Rack, the assigned alter-
nate modulation or dynamic modulation will be controlled.
When this message is received, the result will be the same as
when the controller is operated.
• In Combination and Multi modes, transmission/
reception of this message can be turned on/off
independently for each timbre/track ( p.42, 60
"Realtime Control Knob1, 2, 3, 4").
Controller (CC#83) [Bn, 53, vv]
If you assign the above CC# to the B-mode function of a
REALTIME CONTROLS [1]–[4] knob, and operate the corre-
sponding controller of the TRITON-Rack, the assigned alter-
nate modulation or dynamic modulation will be controlled.
When this message is received, the result will be the same as
when the controller is operated.
SW1 modulation (CC#80) [Bn, 50, vv]
SW2 modulation (CC#81) [Bn, 51, vv]
If the above CC# are assigned as the function of "SW1" or
"SW2," operating the switch will transmit this message with
vv=127 [7F] for ON, and vv=00 [00] for OFF, the assigned
alternate modulation or dynamic modulation will be con-
trolled. When this message is received, the result will be the
same as when the controller is operated. Off when vv is 63
[3F] or lower, and On when vv is 64 [40] or higher. (This can
also be set as a B-mode function of the REALTIME CON-
TROLS knobs [1]–[4].)
• In Combination and Multi modes, transmission/
reception of these messages can be turned on/off
independently for each timbre/track ( p.42, 60 "SW1,"
"SW2"
Using controllers of a connected TRITON or other
MIDI device for control
The controllers of a connected TRITON or other MIDI
device, or the control changes assigned to controllers, can be
received to control alternate modulation or dynamic modu-
lation. The controllers and the MIDI messages they transmit
will depend on the type of MIDI device that is connected. As
B-mode functions of the TRITON-Rack's REALTIME CON-
TROLS [1]–[4] knobs, you can select and control MIDI
CC#00–CC#95.
224
Foot controller (CC#04) [Bn, 04, vv]
When this message is received, the effect that is assigned
(alternate modulation or dynamic modulation etc.) will be
applied.
Ribbon controller (CC#16) [Bn, 10, vv]
When this message is received, the effect that is assigned
(alternate modulation or dynamic modulation etc.) will be
applied.
• In Combination or Multi mode, transmission and
reception of this message can be turned on/off for each
timbre/track. ( p.42, 59 "Ribbon CC#16")
Controller (CC#18) [Bn, 12, vv]
When this message is received, the effect that is assigned
(alternate modulation or dynamic modulation etc.) will be
applied.
Foot switch (CC#82) [Bn, 52, vv]
When this message is received, the effect that is assigned
(alternate modulation or dynamic modulation etc.) will be
applied.
Damper pedal (CC#64) [Bn, 40, vv]
When this message is received, the damper effect will be
applied. If this is controlled from a device that has half-
damper functionality, such as the TRITON, the half-damper
effect will be applied. Alternatively, the assigned alternate
modulation or dynamic modulation effect will be applied.
• In Combination and Multi modes, transmission/
reception of this message can be turned on/off
independently for each timbre/track ( p.41, 59
"Damper CC#64").
Sostenuto (CC#66) [Bn, 42, vv]
When this message is received, the sostenuto effect will be
turned on/off. (Off when vv is 63 [3F] or lower, and On
when vv is 64 [40] or higher.)
Soft pedal (CC#67 [Bn, 43, vv]
When this message is received, the soft pedal effect will be
applied. Alternatively, the assigned alternate modulation
effect will be applied.
Controlling the tone/envelope of a program
CC#70-78 control specific parameters of a program. For
details on the program parameters that correspond to each
control change, and how the TRITON-Rack will respond in
each mode when these are received, refer to "TRITON-Rack
operations when control changes are transmitted/received"
( p.218).
Low pass filter cutoff (CC#74) [Bn, 4A, vv]
Resonance level/High pass filter cutoff (CC#71) [Bn, 47, vv]
Filter EG intensity (CC#79) [Bn, 4F, vv]
Release time (CC#72) [Bn, 48, vv]
These messages are transmitted when you operate the TRI-
TON-Rack's REALTIME CONTROLS [1]–[4] knobs in A-
mode. (They can also be set as B-mode functions.)
Sustain level (CC#70) [Bn, 46, vv]
Attack time (CC#73) [Bn, 49, vv]
Decay time (CC#75) [Bn, 4B, vv]
LFO 1 speed (CC#76) [Bn, 4C, vv]
LFO 1 depth (pitch) (CC#77) [Bn, 4D, vv]
LFO 1 delay (CC#78) [Bn, 4E, vv]
These messages are transmitted when assign the above CC#
to the REALTIME CONTROLS [1]–[4] knobs in B-mode and
operate them.
When you operate these, the corresponding program
parameters will be controlled, and the sound and envelope
will change. When these messages are received, the result
will be the same as when the controller is operated. (When