Intermatic PE650 Installation And User Manual page 51

Wave series hand-held remote transceiver panel-mounted transceiver
Table of Contents

Advertisement

Check that the Fireman's Switch is
Working (if installed)
What to do
1.
Make sure all equipment is OFF but power is present
at the panel.
.
Make sure the water valves are in the Pool position
and the VALVE light on the control is OFF.
.
Push Circuit #1 ON to turn on the Filter Pump.
.
Wake up the Hand-Held Remote Transceiver by
pressing any button. The display should show the
actual water temperature of the pool.
5.
On the right hand side of the display is a P and an
S indicating the pool and spa set temperatures. Use
the arrow keys to adjust the pool set point so that
the final set point is higher then the actual water
temperature.
6.
At the bottom of the display, the word HEATING
should come on. This indicates that the heater
should be heating, presuming that the heater is
working properly and the system is wired and
plumbed properly.
.
Verify that the heater is actually heating.
.
Push Circuit #1 OFF to turn off the Filter Pump.
The heater should shut off but the Filter pump
should continue to run while the display on the
Three-circuit Clock starts to count down from its
programmed setting.
9.
When the clock's programmed setting reaches zero,
the Filter pump should shut off.
If you can't complete this procedure successfully, follow
the steps below to troubleshoot.
Check Out and Troubleshooting