Checking The Charging Voltage; Checking The Open-Circuit Current - Husqvarna FC 250 2016 Repair Manual

Hide thumbs Also See for FC 250 2016:
Table of Contents

Advertisement

15 WIRING HARNESS, BATTERY
15.5
15.6
132

Checking the charging voltage

en-circuit current
Guideline
The charging current, charging voltage, and charging time
must not be exceeded.
Charge the battery regularly
when the motorcycle is not
in use
-
Finishing work
Mount the seat.
(a
p. 95)
-
Install the air filter box cover.
Condition
The battery must be fully functional and completely charged.
-
Preparatory work
Remove the air filter box cover.
-
Remove the seat.
(�
p. 94)
-
Main work
Start the motorcycle to check the function.
Measure the voltage between the specified points.
V
Measuring point
Plus
Ground(-)
Charging voltage
I
5,000 rpm
If the displayed value is less than the specified value:
-
Check the plug-in connections from the alternator to
the voltage regulator.
-
Check the plug-in connections from the voltage regu-
lator to the wiring harness.
-
Check the stator winding of the alternator.
If the displayed value is greater than the specified value:
-
Change the voltage regulator.
-
Preparatory work
Press and hold the kill switch � while the engine is idling until
the engine stops.
-
Remove the air filter box cover.
-
Remove the seat.
(a
p. 94)
3 months
(a
p. 90)
(a
p. 90)
(�
p. 13)
(+) - Measuring point
13.5 ... 15.0 V
1
(a
p. 249)
(�
p. 90)