4.4.3   Disabling Auto-Sync
Step 1 : From a host command line, use the
bit is currently enabled (08, bold in the following example):
sg_modes <dev> --page=0x20 --llbaa
HGST
Mode parameter header from MODE SENSE(10):
Mode data length=24, medium type=0x00, specific param=0x00, longlba=0
Block descriptor length=0
>> page_code: 0x20, page_control: current
00
Step 2 : Use the
sg_wr_mode <dev> --dbd -s --page=0x20 --
contents=a0,0e,01,00,00,00,00,00,00,00,00,00,00,00,00,00 --
mask=00,00,00,00,00,00,00,00,00,00,00,00,00,00,08,00
Step 3 : Use the
bold in the following example):
sg_modes <dev> --page=0x20 --llbaa
HGST
Mode parameter header from MODE SENSE(10):
Mode data length=24, medium type=0x00, specific param=0x00, longlba=0
Block descriptor length=0
>> page_code: 0x20, page_control: current
00
4.5   OOBM Management Overview
The Ultrastar Data102 uses an implementation of DMTF Redfish for out-of-band system management. All the
SES enclosure information can be obtained through the out-of-band management port using RESTful API
calls to the management port over HTTPS. The OOBM ports are configured for DHCP by default.
4.5.1   Configuring OOBM Network Settings Using SES
Changing the OOBM Network Configuration
Step 1 : To change the OOBM network configuration, enter the following:
sg_wr_mode
contents=e3,01,00,1A,<IOM>,00,00,00,<setting>,00,00,00,<IPaddr>,
<netmask>,<gateway>,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00
Where:
<dev>
<IOM>
<setting>
<IPaddr>
H4102-J
3010
peripheral_type: enclosure services device [0xd]
a0 0e 01 00 00 00 00 00
utility to disable the enclosure's Auto-Sync VPD bit:
sg_wr_mode
utility to verify that the enclosure's Auto-Sync VPD bit is now disabled (00,
sg_modes
H4102-J
3010
peripheral_type: enclosure services device [0xd]
a0 0e 01 00 00 00 00 00
<dev>
--dbd --page=0x23,0x01 --
= the device SEP sg handle
= 01 (IOMA) or 02 (IOMB)
= 00 (static) or 01 (DHCP)
= The IP address in four pairs of two-digit hex codes