Western Digital Ultrastar ScaleUp SE4U102 User Manual page 241

Table of Contents

Advertisement

User Guide
Table 48: SAS Cable connections for Configuration 2
Configuration 3
Configuration 3 allows up to two redundantly configured hosts to view a specific zone group of drives.
Each host will be able to view up to 51 drives that are mapped to both IOMs. Each zone group will display
all of the devices that are contained within that zone. If a drive slot is not populated, it will still be part of
that zone group, but it will not display any results in enclosure management until the drive slot has been
populated. In this configuration, the enclosure is divided into two zone groups as shown in the image
below (represented by two different colors). Each zone group matches to three SAS ports on each IOM
(represented by a matching color) to allow for the connections to two different hosts.
• In-band management: Configuration 3 can be initiated in-band with the
passing
as the zoning configuration option. See:
03
senddiag command.
• Out-of-band management: Configuration 3 can be initiated out-of-band by passing
ZoningConfig
Redfish POST:
/redfish/v1/Systems/Self/Storage/<Enclosure Logical ID>/Actions/Storage.Zoning
{ "ZoningConfig": "3" }
cURL POST:
curl -X POST -k -u admin:admin -H "Content-type: application/json"
https://<IP Address>/redfish/v1/Systems/Self/Storage/<Enclosure Logical ID>/Actions/
Storage.Zoning -d
Host
Host 1
Host 2
Host 3
option for each IOM. The following are example Redfish and cURL POSTcommands:
Enclosure IOM SAS Port
A1
A2
B1
B2
A3
A4
B3
B4
A5
A6
B5
B6
sg_senddiag