Western Digital Ultrastar ScaleUp SE4U102 User Manual page 226

Table of Contents

Advertisement

User Guide
Step 2 : Upgrade the enclosure firmware using sg_ses_microcode by executing the following command:
sg_ses_microcode <dev> -m 0xe -N -b 4096 -I <filename> -vv
Step 3 : Press Enter.
The firmware begins loading onto the IOMs. The upgrade can take up to 20 minutes to
complete.
Important: Do not unzip/extract the tar.gz file. Doing so will result in errors during
the firmware upgrade process.
Attention: If the OOBM is not being used, query Page Eh by executing the
following command
sg_ses <device> -p0xe
Important: Due to the firmware image being a .tar.gz file, the enclosure has to
unpack and load the firmware onto the respective ICs which may take up to 15
minutes. Once the sg_ses_microcode command is issued wait 20 minutes to
ensure the enclosure has time to perform this process. To check the status of this
process, use the Redfish out-of-band management to make a GET request to the
following target:
curl -G
-k -u admin:admin -H "Content-type: application/
json" https://<ip address>/redfish/v1/UpdateService/Actions/
UpdateService.SimpleUpdate/Status
Note: Execute the command until you see the following result:
{"ErrorCode":0,"StatusCode":2,"Description":"FW update completed.
Waiting for activation.","EstimatedRemainingMinutes":0}
Attention: If the OOBM is not being used, query Page Eh by executing the
following command
sg_ses <dev> -p 0xe
the output may be inaccurate, please ignore and issue the command again. The
string to observe for download microcode status is "Complete, no error, start
after hard reset or power cycle [0x11]" before proceeding to the activate step.
Example output:
sg_ses <dev> -p 0xe
HGST
H4102-J
<FW Version>
Download microcode status diagnostic page:
number of secondary subenclosures: 0
generation code: 0x0
subenclosure identifier: 0 [primary]
download microcode status: Complete, no error, start after
hard reset or power cycle [0x11]
download microcode additional status: 0x0
download microcode maximum size: 1703914 bytes
download microcode expected buffer id: 0x0
4.3 Firmware Upgrade
.
. The first time this command is issued,
4. Management
210

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultrastar data1021ex1231

Table of Contents