Western Digital Ultrastar ScaleUp SE4U102 User Manual page 240

Table of Contents

Advertisement

User Guide
Configuration 2
Configuration 2 allows up to three redundantly configured hosts to view a specific zone group of drives.
Each host will be able to view up to 34drives that are mapped to both IOMs. Each zone group will display
all of the devices that are contained within that zone. If a drive slot is not populated, it will still be part of
that zone group, but it will not display any results in enclosure management until the drive slot has been
populated. In this configuration, the enclosure is divided into three zone groups as shown in the image
below (represented by three different colors). Each zone group matches to a pair of SAS ports on each
IOM (represented by a matching color) to allow for the connections to three different hosts.
• In-band management: Configuration 2 can be initiated in-band with the
passing
as the zoning configuration option. See:
02
senddiag command.
• Out-of-band management: Configuration 2 can be initiated out-of-band by passing
ZoningConfig
Redfish POST:
/redfish/v1/Systems/Self/ Storage/<Enclosure Logical ID>/Actions/Storage.Zoning
{ "ZoningConfig": "2" }
cURL POST:
curl -X POST -k -u admin:admin -H "Content-type: application/json"
https://<IP Address>/redfish/v1/Systems/Self/Storage/<Enclosure Logical ID>/Actions/
Storage.Zoning -d
'{"ZoningConfig" : "2"}'
Figure 249: Configuration 2
Connect the host servers to the enclosure using SAS cables in the configuration listed in the table below.
The left side of the table displays the host number, and the right side displays the appropriate IOM SAS
ports on the enclosure for that host.
option for each IOM. The following are example Redfish and cURL POST commands:
sg_senddiag
sg_senddiag Command (page 227)
4. Management
4.7 Zoning
command by
for the actual
as the
2
224

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultrastar data1021ex1231

Table of Contents