Fx5U Cpu Module - Mitsubishi Electric MELSEC iQ-F Series User Manual

Programmable
Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

FX5U CPU module

[2]
[3]
[6]
[5]
[4]
[3]
[2]
[1]
No.
Name
[1]
DIN rail mounting hook
[2]
Expansion adapter connecting hooks
[3]
Terminal block cover
[4]
Built-in Ethernet communication
connector
[5]
Top cover
[6]
CARD LED
RD LED
SD LED
SD/RD LED
[7]
Expansion board connector cover
[8]
Input display LED
[9]
Extension connector cover
[10]
PWR LED
ERR LED
P.RUN LED
BAT LED
[11]
Output display LED
3 PART NAMES
68
3.1 CPU Module
[7]
[8]
[9]
[10]
[11]
Description
Hook for mounting a CPU module on a DIN rail of DIN46277 (width: 35mm).
When connecting an expansion adapter, secure it with these hooks.
Cover for protecting the terminal block.
The cover can be opened for wiring. Keep the cover closed while equipment is running (power is on).
Connector for connection with Ethernet-compatible devices. (with cap)
For a connector that is not connected with the Ethernet cable, attach the cap provided as an accessory to
block dust or dirt.
For details, refer to MELSEC iQ-F FX5 User's Manual (Ethernet Communication).
Cover for protecting the SD memory card slot, the RUN/STOP/RESET switch, and others.
The built-in RS-485 communication terminal block, built-in analog I/O terminal block, RUN/STOP/RESET
switch, SD memory card slot, and others are located under this cover.
Indicates whether an SD memory card can be used or not.
On: Can be used or cannot be removed
Flashing:In preparation
Off: Not inserted or can be removed
Turns on when the CPU module is receiving data through built-in RS-485 communications.
Turns on when the CPU module is sending data through built-in RS-485 communications.
Turns on when the CPU module is sending or receiving data through built-in Ethernet communications.
Cover for protecting expansion board connector, battery, or others.
Connect the battery under this cover.
Turns on when input is on.
Cover for protecting the extension connector.
Connect the extension cable of an extension module to the extension connector under the cover.
Indicates whether the CPU module is powered or not.
On: Powered
Off: Not powered or hardware error (Page 253 Checking with LEDs)
Indicates the error status of the CPU module. ( Page 253 Checking with LEDs)
On: Error or hardware error
Flashing:Factory default setting, error, hardware error, or resetting
Off: Normal operation
Indicates the program running status.
On: Normal operation
Flashing:Paused, stopped (program mismatched), or online program change (PAUSE or RUN was set at
the time of online program change.) (Page 253 Checking with LEDs)
Off: Stopped or stop error
Indicates the battery status.
Flashing:Battery error
Off: Normal operation (Page 253 Checking with LEDs)
Turns on when output is on.

Advertisement

Table of Contents
loading

Table of Contents