■Wiring example (when 24VDC external power supply is used)
NPN open collector transistor output rotary encoder
Sink wiring
When using the input of FX5U-32MT/ES
L
Class-D grounding
N
S/S
0V
1.5kΩ
24V
X2
FX5U-
X3
32MT/ES
PNP open collector transistor output rotary encoder
Source wiring
When using the input of FX5U-32MT/ESS
L
Class-D grounding
N
S/S
0V
24V
1.5
X2
FX5U-
X3
32MT/ESS
*1 The grounding resistance should be 100 or less.
13 WIRING
216
13.7 Wiring Examples for Various Uses
Rotary encoder
24VDC
Fuse
24V
*1
0V
Phase A
Phase B
Phase Z
Rotary encoder
24VDC
Fuse
24V
*1
0V
Phase A
Phase B
Phase Z
When using the input of FX5-16ET/ES-H
Fuse
L
Class-D grounding
N
S/S
0V
FX5U-
24V
32MT/ES
1.5kΩ
S/S
X2
FX5-
X3
16ET/ES-H
When using the input of FX5-16ET/ESS-H
Fuse
L
Class-D grounding
N
S/S
0V
FX5U-
24V
32MT/ESS
S/S
1.5
X2
FX5-
X3
16ET/ESS-H
Rotary encoder
24VDC
24V
*1
0V
Phase A
Phase B
Phase Z
Rotary encoder
24VDC
24V
*1
0V
Phase A
Phase B
Phase Z