Cast Bypass Top Plate Removal/Installation; Fan Operation Into Auto Mode - FPI CI2700 Manual

Catalytic wood-fired fireplace insert
Table of Contents

Advertisement

CAST BYPASS TOP PLATE REMOVAL /
INSTALLATION
1. Allow the stove to burn out and cool down, until cool to touch.
2. Open stove door to access secondary air tube.
3. Remove secondary air tube–(see previous page).
4. Remove 2 bolts in locations shown and remove stainless steel front lip
retainer.
View of inside top of stove
5. Loosen the 4 bolts holding the bottom shield. Slide shield towards door
opening to remove.
6. 8 bolts secure the cast bypass top plate to the roof of the stove.
Before removing the bolts securing the cast bypass - support the cast up
with 2 X 12-1/4" 2 x 4 's. The cast bypass opening weighs 30lbs - DO NOT
REMOVE the bolts on the cast bypass prior to supporting the weight to
avoid damage and injury.
View of inside top of stove
7. Remove the cast bypass opening top plate and replace.
8. Reverse steps to reinstall.
Stainless front lip retainer
Bottom shield

FAN OPERATION INTO AUTO MODE

If fan will not come on in auto mode see the following possible causes and
solutions:
Possible causes:
- Bypass damper is open
- Brand new unit or first burn of the season
- No ember bed established (embers or coals, not to be mistaken with ashes)
- Primary damper is set to low (all the way to the right)
- There are only a couple small logs on fire or fire is almost out
- Mechanical issues or defects
Solutions:
- Close bypass once unit is at optimum temperature
- Establish a couple inch ember bed
- Set damper between medium to high (middle or all the way to the left)
- Add a few more logs onto the fire
- See your authorized dealer
NOTE: The temperature displayed on the catalyst monitor has nothing to
do with the activation temperature in auto for the fan.
The automatic sensor for this appliance is located at the firebox
base. If the temperature at this location is not met, the fan will not
come on. It is crucial on this appliance to get this up to operating
temperature so that the catalyst is activated and bypass may be
closed to retain heat within the firebox.