Emission testing instructions CI2700
Volume: 1.83 cu.ft.
Low and Medium
High before Low and Medium – no sampling. Air set to High Setting
Fan on high at 20 min after loading main fuel load
Kindling ~ 3.0lb
Startup fuel ~ 5.0lb
Procedure
Start with a couple pieces of crumbled paper in between and 1.8 lbs kindling. Adjust the door opening
for less smoke and establish a good fire. Keep the door open in that position for 2 – 3 min.
At ~0.8lb load the remainder of the kindling fuel and 1 lb of start-up fuel close door soon after loading.
Let flame establish for 2-3 minutes then close bypass.
At ~1 lb add 2 lbs of start-up fuel, ensure flame is established prior to closing door (30-60 seconds).
At ~2 lbs load remaining SU fuel, ensure flame is established prior to closing door (30-60 seconds).
At low end of coal bed range load the high load. Close the door right away.
At 20 min turn on the fan on high.
Low and Medium test load
Load heavier logs to the bottom/back.
Keep the door open a couple seconds so there is a strong fire going.
Air adjustment
Medium & Low
At 6-7 min set to test setting.
Fan on high at 20 min.