Run 1 Data.xlsm
BOX B TEST DATA - ASTM E3053 / ASTM E2515
Client:
FPI
Model:
CI2700
Run #:
1
Gas Meter
Elapsed
Sample
3
Time (min)
Rate (cfm)
(ft
)
192
27.678
0.149
193
27.821
0.143
194
27.969
0.148
195
28.112
0.143
196
28.258
0.146
197
28.402
0.144
198
28.548
0.146
199
28.693
0.145
200
28.839
0.146
201
28.985
0.146
202
29.129
0.144
203
29.276
0.147
204
29.419
0.143
205
29.565
0.146
206
29.707
0.142
207
29.855
0.148
208
29.996
0.141
209
30.143
0.147
210
30.284
0.141
211
30.432
0.148
212
30.572
0.140
213
30.718
0.146
214
30.856
0.138
215
30.999
0.143
Avg/Tot
30.999
0.144
PFS-TECO
Job #:
Tracking #:
Technician:
Date:
Particulate Sampling Data
Meter
Orifice dH
Meter
Vacuum
(in H
O)
Temp (°F)
2
(in Hg)
2.14
96
0.97
2.14
96
3.33
2.13
96
1.32
2.12
96
1.38
2.12
96
1.96
2.13
96
3.37
2.13
96
3.33
2.13
96
1.73
2.12
96
2.44
2.13
96
3.16
2.13
96
0.92
2.13
96
0.82
2.13
96
1.15
2.13
96
2.21
2.12
96
1.18
2.13
96
0.96
2.14
96
1.91
2.13
96
3.2
2.11
96
1.95
2.12
96
3.24
2.10
96
1.15
2.10
96
1.32
2.11
96
2.92
2.10
96
2.92
2.14
88
2.05
Page 20 of 26
18-447
0020
SJB
1/28/2019
Pro. Rate
Flue Draft
Filter (°F)
(in H
(%)
102
85
97
85
101
85
97
86
99
86
98
85
99
86
99
85
99
85
99
85
98
86
100
86
97
86
99
86
97
85
101
85
96
85
100
85
96
86
101
86
95
86
100
86
94
85
98
85
100
Flue Gas Data
CO
(%)
CO (%)
2
O)
2
-0.070
6.58
0.01
-0.080
6.41
0.03
-0.070
6.29
0.03
-0.070
6.44
0.00
-0.070
6.21
0.02
-0.080
6.34
0.01
-0.060
6.17
0.02
-0.070
6.16
0.00
-0.080
6.18
0.01
-0.070
6.10
0.01
-0.060
5.89
0.06
-0.080
5.83
0.04
-0.080
5.83
0.03
-0.070
5.79
0.06
-0.080
5.89
0.00
-0.070
5.83
0.02
-0.090
5.81
0.01
-0.060
5.93
0.01
-0.060
5.83
0.05
-0.070
5.82
0.05
-0.080
5.81
0.07
-0.070
5.95
0.05
-0.070
6.01
0.06
-0.070
6.22
0.03
7.83
0.12