Sampling Methods; Analytical Methods Description; Calibration, Quality Control And Assurances; Appliance Sealing And Storage - FPI CI2700 Manual

Catalytic wood-fired fireplace insert
Table of Contents

Advertisement

Project # 18-447
Model: CI2700

Sampling Methods

ASTM E2515 was used in collecting particulate samples. The dilution tunnel is 6 inches
in diameter. All sampling conditions per ASTM E2515 were followed. No alternate
procedures were used with the exception of caveats described in ALT-125: Pall TX40
Emfab filters were used, filter temperatures were maintained between 80 and 90°F for
all tests, filters were weighed in pairs where applicable, and no sampling intervals fell
outside of proportional rates of +/- 10%.

Analytical Methods Description

All sample recovery and analysis procedures followed ASTM E2515 procedures. At the
end of each test run, filters, O-Rings and probes were removed from their housings,
dessicated for a minimum of 24 hours, and then weighed at 6 hour intervals to a
constant weight per ASTM E2515-11 Section 10.

Calibration, Quality Control and Assurances

Calibration procedures and results were conducted per EPA Method 28R, ASTM
E2515-11 and ASTM E3053. Test method quality control procedures (leak checks,
volume meter checks, stratification checks, proportionality results) followed the
procedures outlined.

Appliance Sealing and Storage

Upon completion of testing, the appliance was secured with metal strapping and the
seal below was applied, the appliance was then returned to the manufacturer's location
at: 6988 Venture St, Delta, BC V4G 1H4, Canada, for archival.

Sealing Label

Page | 16