FPI CI2700 Manual page 145

Catalytic wood-fired fireplace insert
Table of Contents

Advertisement

Run 2 Data.xlsm
PM
- Particulate emission rate for low or medium fire test runs, g/hr
R
ASTM E3053 equation (12)
PM
= 60(E
/θ)
R
T
Where,
E
=
Total particulate emissions for low or medium fire test runs from Test Method E2515, g
T
Sample Calculation:
E
=
7.59
T
θ
=
PM
=
R
PM
=
0.54 g/hr
RH
PM
- Particulate emission factor for high fire test run, g/dry kg of fuel burned.
FH
ASTM E3053 equation (13)
PM
= E
/M
F
T
TFBdb
Sample Calculation:
E
=
7.59
T
M
=
8.12
TFBdb
PM
=
7.59
FH
=
0.93 g/kg
PFS-TECO
849
60( 7.59
/
849 )
/
8.12
Page 17 of 17