Run 2 Data.xlsm
BOX B TEST DATA - ASTM E3053 / ASTM E2515
Client:
FPI
Model:
CI2700
Run #:
2
Gas Meter
Elapsed
Sample
3
Time (min)
Rate (cfm)
(ft
)
640
94.731
0.149
650
96.223
0.149
660
97.718
0.150
670
99.210
0.149
680
100.700
0.149
690
102.193
0.149
700
103.687
0.149
710
105.179
0.149
720
106.669
0.149
730
108.162
0.149
740
109.655
0.149
750
111.146
0.149
760
112.636
0.149
770
114.130
0.149
780
115.622
0.149
790
117.111
0.149
800
118.602
0.149
810
120.095
0.149
820
121.587
0.149
830
123.076
0.149
840
124.566
0.149
849
125.909
0.134
Avg/Tot
125.909
0.148
PFS-TECO
Job #:
Tracking #:
Technician:
Date:
Particulate Sampling Data
Meter
Orifice dH
Meter
Vacuum
(in H
O)
Temp (°F)
2
(in Hg)
2.26
94
-0.86
2.26
94
-0.83
2.25
94
-3.07
2.27
94
-3.08
2.26
94
-1.14
2.26
93
-0.7
2.25
93
-0.71
2.26
93
-2.98
2.26
93
-3.21
2.26
93
-0.74
2.27
93
-3.16
2.26
93
-1.12
2.26
93
-0.67
2.27
93
-2.19
2.27
93
-2.74
2.25
93
-0.81
2.25
92
-0.58
2.25
93
-3.08
2.27
93
-1.8
2.27
92
-1.06
2.26
93
-3.11
2.27
92
-2.96
2.20
94
-1.89
Page 16 of 19
18-447
0020
SJB
1/29/2019
Pro. Rate
Flue Draft
Filter (°F)
(in H
(%)
100
85
100
84
100
84
100
85
100
84
100
84
100
85
100
85
100
85
100
85
100
85
100
85
100
86
100
86
100
85
100
85
100
86
100
86
100
86
100
85
100
85
90
85
100
Flue Gas Data
CO
(%)
CO (%)
2
O)
2
0.000
0.20
0.00
0.010
0.09
0.02
-0.010
0.12
0.01
-0.010
0.16
0.02
-0.020
0.24
0.00
-0.010
0.00
0.02
-0.010
0.21
0.00
0.010
0.11
0.03
-0.010
0.12
0.00
0.000
0.14
0.02
0.000
0.09
0.02
0.000
0.19
0.00
0.010
0.12
0.03
0.000
0.11
0.04
-0.010
0.05
0.03
0.000
0.24
0.00
0.000
0.11
0.04
0.000
0.17
0.03
0.000
0.22
0.01
0.010
0.28
0.01
0.000
0.18
0.02
0.000
0.23
0.00
3.98
0.18