FPI CI2700 Manual page 22

Catalytic wood-fired fireplace insert
Table of Contents

Advertisement

SECTION 2 – Test Conditions Summary
Model Name(s)/Number(s)
Usable Firebox Volume - ft
Convection Air Fan (No, Standard, Optional)
Test Run #
Date Tested
Test Run Category (L, M, H)
Average Barometric Pressure - in Hg
Max. Observed Ambient Temp - °F
Min. Observed Ambient Temp - °F
Max. Observed Filter Temp - °F
Test Run Air Settings
Primary (measured up from minimum)
Secondary (measured up from minimum)
Convection Air Fan Setting
Test Fuel Load
Cordwood Fuel Species
Specific Gravity (from Table 1)
Higher Heating Value - Btu/lb (from Annex A1)
Nom. Test Fuel Load Piece Length - in.
Number of Test Fuel Pieces
Test Fuel Weight
Kindling - As Fired lb
Kindling Wt. - As % of Test Fuel Load
Kindling Moisture - % DB
Kindling - kg DB
SU Fuel - As Fired lb
SU Fuel Wt. - As % of Test Fuel Load
SU Fuel Moisture - % DB
SU Fuel - kg DB
Test Fuel Load - As Fired lb
Ave. Test Fuel Load MC % DB
Test Fuel Load - kg DB
Test Fuel Loading Density - lb/ft
Residual SU Fuel Wt. - As Fired lb
Residual SU Fuel Wt. - As % of Test Fuel Load
Test Run Duration - minutes
Test Run Duration - h
Run Duration of High Fire Load Only - minutes
Run Duration of High Fire Load Only - h
Test Fuel Load Wt. at End of Test - As Fired lb
Total Total Fuel Burned - kg DB
% Test Fuel Load Wt. at End of Test
3
3
CI2700, HI500
1.83
Optional
1
2
1/28/2019
1/29/2019
H
L
30.11
70
65
87
Maximum
Minimum
Fixed
Fixed
High
High
Maple
Maple
0.6
8587
17
5
3.00
16%
10%
1.24
5.05
27%
21%
1.90
18.63
21.6%
6.95
10.18
2.00
11%
215
3.58
167
2.78
2
8.27
10.7%
3
1/30/2019
M
29.89
29.84
71
72
65
66
87
87
0.078"
Fixed
High
Maple
0.6
0.6
8587
8587
17
17
5
5
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
na
21.74
21.08
21.5%
22.0%
8.13
7.85
11.88
11.52
na
na
na
na
849
360
14.15
6.00
na
na
na
na
0
0
8.13
7.85
0.0%
0.0%

Advertisement

Chapters

Table of Contents
loading

Table of Contents