Run 1 Data.xlsm
PM
- Particulate emission rate for high fire test run, g/hr;
RH
ASTM E3053 equation (9)
PM
= 60(E
RH
TH
H2
Where,
E
=
Total particulate emissions for high fire test run including kindling and start-up, g
TH
θ
=
Total duration of high fire test run, from ignition of kindling to end of test run, min.
H2
Sample Calculation:
E
=
11.75
TH
θ
=
215
H2
PM
=
60( 11.75 /
RH
PM
=
3.28 g/hr
RH
PM
- Particulate emission factor for high fire test run, g/dry kg of fuel burned.
FH
ASTM E3053 equation (10)
PM
= E
/M
FH
TH
TFBHdb
Sample Calculation:
E
=
11.75
TH
M
=
8.27
TFBHdb
PM
=
11.75
FH
=
1.42 g/kg
PFS-TECO
)
215 )
/
8.27
Page 16 of 17