Digital Catalytic Combustor Monitor - FPI CI2700 Manual

Catalytic wood-fired fireplace insert
Table of Contents

Advertisement

installation
|
14

DIGITAL CATALYTIC COMBUSTOR MONITOR

The CI2700/HI500 is equipped with a provision to accept a catalytic tempera-
ture monitoring device. Please follow instructions below for the installation of
the probe. Follow the user instructions of the catalytic monitoring device for
product set up and details.
1. Remove two (2) bolts from the top of the unit to remove plate as shown
below.
Remove 2 bolts to remove plate
2. Locate the 7/16'' bolt below the metal and remove.
Remove bolt and recycle
14 | CI2700/HI500 Wood Insert
3. Reinstall the plate removed in Step 1 and insert the temperature probe
through the plate and into the hole created by removing the bolt in Step 2.
Device
Probe
4. Complete the installation of the CI2700/HI500. Ensure temperature probe
wire is routed behind the faceplate and to the left side of the unit. Plug in
the monitoring device.
5. Monitoring device can be attached to the unit (with supplied velcro) on the
hanger or the hearth beside the fireplace.
Monitor on hanger
Important: The catalytic monitor probe which is supplied with
this appliance must be installed prior to sliding the unit
into final position in the masonry or factory built fireplace.
Probe
Install temperature probe
Monitor on hearth