Run 2 Data.xlsm
Heat Transfer Efficiency
Test Load Weight (dry kg)
VERSION:
PFS-TECO
B415.1 Efficiency Results
Manufacturer:
Model:
Date:
Run:
Control #:
Test Duration:
Output Category:
Test Results in Accordance with CSA B415.1-09
Overall Efficiency
Combustion Efficiency
Output Rate (kJ/h)
Burn Rate (kg/h)
Input (kJ/h)
MC wet (%)
MC dry (%)
Particulate (g )
CO (g)
Test Duration (h)
Emissions
g/MJ Output
g/kg Dry Fuel
g/h
g/min
lb/MM Btu Output
Air/Fuel Ratio (A/F)
2.2
FPI
CI2700
01/29/19
2
18-447
850
Low
HHV Basis
76.9%
96.5%
79.7%
8,741
0.57
11,366
8.07
17.69
21.49
7.59
720
14.17
Particulate
0.06
0.94
0.54
0.01
0.14
29.41
12/14/2009
Page 3 of 19
LHV Basis
82.3%
96.5%
85.2%
8,292
(Btu/h)
1.25
(lb/h)
10,781
(Btu/h)
17.78
dry lb
CO
5.82
89.31
50.85
0.85
13.52

Advertisement