FPI CI2700 Manual page 110

Catalytic wood-fired fireplace insert
Table of Contents

Advertisement

Run 3 Data.xlsm
BOX B TEST DATA - ASTM E3053 / ASTM E2515
Client:
FPI
Model:
CI2700
Run #:
3
Gas Meter
Elapsed
Sample
3
Time (min)
Rate (cfm)
(ft
)
352
51.995
0.148
353
52.144
0.149
354
52.293
0.149
355
52.441
0.148
356
52.590
0.149
357
52.737
0.147
358
52.887
0.150
359
53.034
0.147
360
53.184
0.150
Avg/Tot
53.184
0.148
PFS-TECO
Job #:
Tracking #:
Technician:
Date:
Particulate Sampling Data
Meter
Orifice dH
Meter
Vacuum
(in H
O)
Temp (°F)
2
(in Hg)
2.22
97
-1.44
2.21
97
-0.75
2.22
97
-1.16
2.22
97
-2.78
2.21
97
-2.62
2.22
97
-0.72
2.21
97
-3.14
2.21
97
-2.4
2.22
97
-0.69
2.21
93
-1.83
Page 33 of 42
18-447
0020
SJB
1/30/2019
Pro. Rate
Flue Draft
Filter (°F)
(in H
(%)
98
85
99
85
99
86
98
86
99
86
98
85
100
85
98
85
100
85
100
Flue Gas Data
CO
(%)
CO (%)
2
O)
2
-0.030
5.18
0.00
-0.040
5.23
0.00
-0.030
5.16
0.00
-0.040
5.16
0.00
-0.040
5.26
0.00
-0.050
5.05
0.00
-0.040
4.92
0.00
-0.020
5.02
0.00
-0.040
5.15
0.00
7.38
0.37