FPI CI2700 Manual page 53

Catalytic wood-fired fireplace insert
Table of Contents

Advertisement

Client: FPI
Model: CI2700
Pre-Test Notes
Pre-Test Start Time:
Air Control Setting:
Time
N/A
High Fire test begins from cold start.
Test Notes
Test Burn Start Time:
Air Control Setting:
Time
0 min
Starting with 1.8 lbs of kindling and ~6 pieces of printer paper, lit fuel with propane torch for 15
seconds; door cracked 3".
1.5 min
Door closed down to 1"
2 min
Door latched closed
7 min
@ 0.7 lbs, added remaining kindling fuel (1.2 lbs) and a couple pieces of start-up fuel (1.0 lbs);
door open 45 seconds
9 min
Bypass closed
26 min
@ 1.0 lbs, added 1.9 lbs of start-up fuel; door open 45 seconds
33 min
Changed both front filters, due to plugging
35 min
@ 1.9 lbs, added remaining start-up fuel pieces (2.1 lbs); door open 30 seconds
47 min
@2.0 lbs, leveled coal bed, zeroed scale and loaded test fuel, door closed 20 seconds after
loading completed
60 min
Changed 1-hour filter
68 min
Turned fan on high, per manufacturer's instructions
215 min
End of Test
Test Burn End Time:
Calibration Gas Values:
Calibration Results:
Zero
10:42
Time
CO
0.00
2
CO
0.000
Flue Gas Probe Leak Check:
Technician Signature:
ASTM E3053 Wood Heater Run Sheets
Job Number: 18-447
Run Number: 1
Wood Heater Run Notes
N/A
N/A
11:17
Fully Open
14:52
Flue Gas Concentration Measurement
Span Gas
Mid Gas
Pre Test
Mid
10:48
10.08
2.512
Initial: No Leakage
Notes
Notes
CO
(%): 16.93
CO (%): 4.330
2
CO
(%): 10.00
CO (%): 2.51
2
Span
Zero
10:44
15:36
16.93
0.02
4.330
-0.024
Final: No Leakage
Date:
Tracking #: 0020
Test Date: 1/28/2019
Post Test
Mid
Span
15:30
15:33
10.04
16.86
2.472
4.270
1/28/2019
Page 1 of 3