Run 2 Data.xlsm
BR - Dry burn rate for low and medium fire test runs, lb/h (kg/h)
ASTM E3053 equation (8)
Where,
Sample Calculation:
PFS-TECO
60 M
TFBdb
BR =
θ
= Total test run duration for low or medium fire test run, min.
θ
M
=
17.89
TFBdb
=
849
θ
60 x 17.89
BR
=
849
1.26
BR
=
lb/hr
=
0.57
kg/hr