FPI CI2700 Manual page 164

Catalytic wood-fired fireplace insert
Table of Contents

Advertisement

2
As required in Subpart
AAA,
section 60.354(d), you or your approved test
laboratory
must also
measure the first hour of particulate
matter
emissions for each
test
run
using
a separate filter in
one of the two parallel sampling
trains.
These
results
must be reported separately and also
included in the total particulate
matter
emissions
per
run. Also,
as required
by
Subpart
AAA,
section
60.534(e),
you
must have
your approved
laboratory
measure the
efficiency,
heat
output,
and carbon monoxide emissions of
the tested
wood
heater using
CSA-B415.1-10. For
measurement of particulate
matter
emission
concentrations,
ASTM 2515-11 must be used.
The following change to ASTM E3053-17
must be
followed:
1. Coal bed conditions prior to
loading test fuel.
The coal
bed
shall
be
a
level plane
without
valleys or ridges for all
test runs
in
the
high, low,
and
medium burn
rate categories.
The following changes to ASTM E2515-11
must be
followed
:
1. The filter temperature must
be maintained between
80 and 90
degrees
F
during
testing.
2. Filters must be weighed in
pairs to
reduce weighing error
propagation;
see ASTM 2515-
11
,
Section
10.2.1
Analytical
Procedure.
3.
Sample filters
must be Pall
TX-40 or equivalent Teflon-coated glass
fiber,
and of 47
mm,
90
mm,
100
mm,
or 110
mm
in
diameter.
4. Only
one point is allowed outside
the+/- 10 percent proportionality
range per test run.
A
copy
of this letter
must be
included
in
each certification test
report
where this alternative test
method is
utilized.
It
is
reasonable that this alternative
test method
approval
be broadly
applicable
to
all wood
heaters subject to the requirements of 40 CFR
part 60,
Subpart AAA. For this
reason,
we will
post thi
s
letter as ALT-125 on our website at http://www3.epa.gov/ttn/emc/approalt.html for use
by
other interested
parties.
As
noted
earlier in
this letter,
this alternative
method
approval is valid
until such time that Subpart AAA is revised or
replaced to
require a
different
cord wood
certification
method,
and at such
time,
this alternative will
be reconsidered
and possibly
withdrawn.