Advertisement

Run 1 Data.xlsm
C
- Concentration of particulate matter in tunnel gas, dry basis, corrected to STP, g/dscf
s
ASTM E2515 equation (13)
m
=
n
C
K
2
s
V
(
)
m
std
Where:
K
=
Constant, 0.001 g/mg
2
m
=
Total mass of particulate matter collected in the sampling train, mg
n
V
=
Volume of gas sampled corrected to dry standard conditions, dscf
m(std)
Sample calculation:
For Train 1:
9.6
C
=
0.001 x
s
31.85
C
=
0.00030 g/dscf
s
For Train 2
9.4
C
=
0.001 x
s
30.21
C
=
0.00031 g/dscf
s
For Ambient Train
0.1
C
=
0.001 x
r
26.04
C
= 0.000004 g/dscf
r