FPI CI2700 Manual page 57

Catalytic wood-fired fireplace insert
Table of Contents

Advertisement

Run 2 Data.xlsm
TEST RESULTS - ASTM E3053 / ASTM E2515
Client:
FPI
Model:
CI2700
Run #:
2
Average Gas Velocity in Dilution Tunnel (ft/sec)
Average Gas Flow Rate in Dilution Tunnel (dscf/hr)
Particulate Concentration, dry-standard (g/dscf)
Difference from Average Total Particulate Emissions (g)
Difference from Average Emissions Factor (g/kg)
Quality Checks
Dual Train Precision
Filter Temps
Face Velocity
Leakage Rate
Ambient Temp
Negative Probe Weight Evaluation
Pro-Rate Variation
PFS-TECO
Burn Rate (kg/hr):
Total Sample Volume (ft
Average Gas Meter Temperature (°F)
Total Sample Volume (dscf)
Average Tunnel Temperature (°F)
Total Time of Test (min)
Total Particulate Catch (mg)
Total PM Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
Final Average Results
Total Particulate Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
HHV Efficiency (%)
LHV Efficiency (%)
CO Emissions (g/min)
Requirement
Each train within 7.5% of average emissions (in
grams), or emission factors within 0.5 g/kg
>80 °F, <90 °F
< 30 ft/min
Less than 4% of average sample rate
55-90 °F
<5% of Total Catch
90% of readings between 90-110%; none greater than
120% or less than 80%
Page 2 of 19
Tracking #:
Technician:
0.57
Ambient
Sample
Sample
Train A
3
)
102.681
126.801
68.3
78.9
102.566
125.454
0.0
6.1
0.0000000
0.0000486
0.00
7.56
0.00
0.53
-
0.93
-
0.02
-
0.00
7.59
0.54
0.93
76.9%
82.3%
0.85
Observed
See Above
Min: 83 / Max: 87
8.1
0 cfm
Min: 65 / Max: 71
Probe Catch Not
Negative
See Data Tabs
Job #:
18-447
0020
SJB
Date:
1/29/2019
Sample
1st Hour Filter
Train B
125.909
8.734
16.18
10995.2
94.2
75.9
120.656
10.254
78.6
849
5.9
4.1
0.0000489
0.0003998
7.61
4.40
0.54
4.40
0.94
0.02
0.00
Result
OK
OK
OK
OK
OK
OK
OK
-
-
-

Advertisement

Chapters

Table of Contents
loading

Table of Contents