Omron SMARTSTEP A Series User Manual page 220

Servomotors/servo drivers
Hide thumbs Also See for SMARTSTEP A Series:
Table of Contents

Advertisement

Troubleshooting
Alarm Table
Code
Alarm
A.04
A.10
A.30
A.32
A.40
A.51
A.70
A.73
A.74
A.7A
A.bF
A.C1
A.C2
A.C3
A.d0
CPF00
CPF01
Warning
A.91
A.92
Note These alarms are not displayed on the alarm indicator on the front of the Servo Driver. They
appears on the display of the Parameter Unit.
5-6
ALM
Error detection function
OFF
Parameter setting error
OFF
Overcurrent
OFF
Regeneration error
OFF
Regeneration overload
OFF
Overvoltage/undervoltage Main circuit DC voltage outside the
OFF
Overspeed
OFF
Overload
OFF
Dynamic brake overload
OFF
Inrush resistance over-
load
OFF
Overheat
OFF
System error
OFF
Runaway detected
OFF
Phase error detected
OFF
Encoder disconnection
detected
OFF
Deviation counter over-
flow
---
Parameter Unit transmis-
sion error 1
---
Parameter Unit transmis-
sion error 2
---
Overload
---
Regeneration overload
Chapter 5
Cause of error
The Servomotor does not match the
Servo Driver.
Overcurrent detected, or improper radi-
ation shield temperature rise detected.
Regeneration circuit damaged due to
large amount of regenerative energy.
Regenerative energy exceeded the
regeneration resistance.
allowable range.
Servomotor rotation speed exceeded
the maximum speed.
Output torque exceeded 120% of rated
torque.
Regenerative energy exceeded the
dynamic brake resistance during
dynamic brake operation.
Inrush current exceeded the inrush
resistance during power supply inrush.
Abnormal temperature rise detected in
radiation shield.
A control circuit system error was
detected.
The Servomotor rotated in the opposite
direction from the command.
The Servomotor's electrical angle was
incorrectly detected
Encoder phase A, B, or S is discon-
nected or shorted.
Deviation counter's residual pulses
exceeded the deviation counter over-
flow level set in Pn505.
Data could not be transmitted after the
power supply was turned ON. (See
note.)
Transmission timeout error (See note.)
A warning occurs before the overload
alarm (A.70) is reached. An alarm may
be generated if the Servomotor contin-
ues to operate.
A warning occurs before the regenera-
tion overload alarm (A.32) is reached.
An alarm may be generated if the Ser-
vomotor continues to operate.