This chapter explains how to install the IES-1248.
2.1 General Installation Instructions
Before you begin, read all the safety warnings in
follow them.
Perform the installation as follows:
1 Make sure the IES-1248 power switch is in the OFF position.
2 Install the hardware. See
3 Connect the frame ground. See
4 See
Chapter 3 on page 53
5 See
Chapter 4 on page 61
6 See
Chapter 5 on page 69
the IES-1248.
2.2 Installation Scenarios
The IES-1248 can be placed on a desktop or rack-mounted on a standard EIA rack. Use the
rubber feet in a desktop installation and the brackets in a rack-mounted installation.
For proper ventilation, allow at least 4 inches (10 cm) of clearance at the front and 3.4 inches
(8 cm) at the back of the IES-1248. This is especially important for enclosed rack installations.
2.2.1 Desktop Installation Procedure
1 Make sure the IES-1248 is clean and dry.
2 Set the IES-1248 on a smooth, level surface strong enough to support the weight of the
IES-1248 and the connected cables. Make sure there is a power outlet nearby.
3 Make sure there is enough clearance around the IES-1248 to allow air circulation and the
attachment of cables and the power cord.
4 Remove the adhesive backing from the rubber feet.
5 Attach the rubber feet to each corner on the bottom of the IES-1248. These rubber feet
help protect the IES-1248 from shock or vibration and ensure space between IES-1248
when stacking.
IES-1248-71/73 User's Guide
Hardware Installation
Appendix B on page
Section 2.2 on page
47.
Section 2.3 on page
for instructions on making front panel connections.
for instructions on connecting the Telco-50 connectors.
for instructions on making power connections and turning on