The following chart gives specifications for the Mini-Cat
pumps, using No. 10 weight oil. The volumetric ratio is
expressed as the proportion of the volume of fluid of the
primary pump compared to the volume of fluid of the
secondary pump.
Model
Pump
Number
Primary
965660
222015
965661
222015
The Typical Installation drawings (Figure 1 and Figure
2) are only guides to setting up the complete Variable
Ratio Mini-Cat system. For assistance in designing a
system to suit your particular needs, contact your near-
est Graco representative.
NOTE:
The reference numbers and letters in the text
correspond to the numbers and letters in the drawings.

Location

Location
Location
Location
Install the proportioner on a flat floor surface.

Connect the Fluid Supply Lines

Connect the Fluid Supply Lines
Connect the Fluid Supply Lines
Connect the Fluid Supply Lines
Connect grounded fluid hoses to the 3/4 npt(f) pump
inlet fittings. If the unit will be pressure fed from sepa-
rate supply units, install a fluid pressure gauge at each
inlet.
8

Specifications

Specifications
Specifications
Specifications
Volumetric Ratio
Secondary
Min.
222012
1:1
222019
2:1

Installation

Installation
Installation
Installation
For example, Model 965660 has a minimum volumetric
ratio of 1:1. At this setting the primary and secondary
pumps combined will deliver an output of 1.1 GPM (4.2
liter/min). The minimum volumetric ratio for Model
965660 is 1:1 and the combined output at that setting is
0.7 GPM (2.6 liters/min).
Output Volume
GPM (liter/min.) at
40 CPM
Max.
Min.
4:1
0.62 (2.3)
8:1
0.56 (2.1)
NOTE:
The pressurized fluid supplies must not exceed
1/4 of the operating fluid pressure of the pump. Pres-
sure above that level will feed right through the pump
and improper rationing will result.

Connect the Static Mixer

Connect the Static Mixer
Connect the Static Mixer
Connect the Static Mixer
Connect a static mixer to the 1/2 npt(m) manifold outlet.
Connect a grounded fluid hose and spray gun to the end
of the static mixer. Tighten all the fittings.
Key for Figure 1 and Figure 2
A
Atomizing Air Regulator
B
Self Relieving Air Valve
C
Catalyst Supply Shut-off Valve M
D
Grounded Fluid Hose
E
Sampling Valve (resin)
F
Mix Manifold
G
Mini-Cat Proportioner
H
Air Oiler
I
Air Filter
J
Main Self Relieving Air Valve
Specifications
Stall Pressure at
50 psi (0.34 MPa,
3.4 bar) inbound
Max.
Min.
1.0 (3.8)
350
(2.4, 24)
0.75 (2.8)
420
(2.9, 29)
K
Resin Supply Pail
L
Solvent Supply
Air Spray Gun
N
Air Supply
O
Static Mixer
P
Fluid Regulator
R
Solvent Shut-off Valve
S
Color Selector Manifold
T
Pressure Relief Valve