Parameter assignment

4.3 PROFIBUS DP parameter assignment

4.3
PROFIBUS DP parameter assignment
4.3.1

Parameter assignment sequence

Parameter assignment sequence
The PROFIBUS DP parameter assignment for the ADI4 DP slave can be generally divided into the
following steps:
1. Step
After inserting the ADI4 DP slave in the configuration, the following parameters are assigned
on a slave-specific basis:
– PROFIBUS parameters (see Section "PROFIBUS parameters (Page 43)")
– Function parameters (see Section "Function parameters (Page 50)")
Step 1 should be carried out first for all ADI4 DP slaves needed in the configuration.
2. Step
Parameter assignment of the equidistant cyclic DP communication (see Section "Parameter
assignment of the DP communication (Page 60)")
Step 2 can be performed last on any ADI4 DP slave. These settings can be transferred to all
other ADI4 DP slaves by means of the adjustment function of the SlaveOM.
4.3.2

Inserting an ADI4 DP slave in the configuration

Procedure
1. To insert an ADI4 DP slave in the configuration, open the hardware catalog using the View >
Catalog menu command.
The ADI4 DP slave can be found at:
– Profile: Standard
SIMATIC Technology CPU
If S7-Technology was installed for the Technology CPU, the ADI4 DP slave is located under:
– Profile: SIMATIC Technology CPU
2. Using a drag-and-drop operation, select the ADI4 DP slave and move it onto to the DP master
system in the station window.
The DP master system is displayed in the station window with the following symbol:
42
PROFIBUS DP > SINUMERIK > ADI4
PROFIBUS DP (DRIVE) > Other FIELD DEVICES > SINUMERIK > ADI4
SIMOTION ADI4 - Analog Drive Interface for 4 Axes