Pin
15
16
17
18-33
34
35
36
37
38-46
47
48
49
50
1) VO Voltage output
K Relay contact
2) Max. current carrying capacity: 2 A for 150 V DC or 125 V AC;
Max. number of switching cycles:
- 24 V DC, 1 A: 10
- 24 V DC, 2 A: 10
3) Max. current carrying capacity: 10 mA (RL: 1 kW - 2 kW)
Prefabricated cables
Article number: 6FX2 002‑3AD01‑☐☐☐☐
Cable length: ≤ 30 m
Information regarding the length codes is provided in:
Reference: /Z/ Catalog NC Z
Resolution of setpoint outputs
The analog setpoint outputs on the interface (X3) have the following resolution: 16-bit,
including sign.
SIMOTION ADI4 - Analog Drive Interface for 4 Axes
Equipment Manual, 07/2017, A5E33446849B
Designation
Type
RF2_1
K
2)
RF3_1
K
2)
RF4_1
K
2)
-
-
BS1
VO
SW2
VO
BS3
VO
SW4
VO
-
-
RF1_2
K
2)
RF2_2
K
2)
RF3_2
K
2)
RF4_2
K
2)
7
5
1)
"Drive enable" of Axis 2, Relay Contact 1
"Drive enable" of Axis 3, Relay Contact 1
"Drive enable" of Axis 4, Relay Contact 1
-
Reference for setpoint of Axis 1
Setpoint of Axis 2 (±10 V)
3)
Reference for setpoint of Axis 3
3)
Setpoint of Axis 4 (±10 V)
-
"Drive enable" of Axis 1, Relay Contact 2
"Drive enable" of Axis 2, Relay Contact 2
"Drive enable" of Axis 3, Relay Contact 2
"Drive enable" of Axis 4, Relay Contact 2
Hardware description