Daikin Perfera RXM R Series Service Manual page 90

Split r32
Table of Contents

Advertisement

3
|
Components
To install the humidity sensor
Service manual
90
Prerequisite: Remove the required plate work, see
1 Disconnect the connector from the humidity sensor PCB.
2 Cut the tie strap that fixes the thermistor.
3 Carefully click the complete humidity sensor PCB assembly out of the indoor
unit.
a Humidity sensor PCB assembly
b Tie strap (thermistor fixation)
4 To install the humidity sensor PCB assembly, see
1 Click the humidity sensor PCB assembly on the indoor unit.
a Humidity sensor PCB assembly
b Tie strap (thermistor fixation)
2 Install the thermistor on the correct location and fix it to the bracket using a
new tie strap.
3 Connect the harness to the humicity sensor PCB assembly.
Is the problem solved?
Yes
No
"3.14 Plate
a
b
"Repair
a
b
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
4
work" [
 151].
procedures" [
4
 89].