Components
To remove the switch box
Service manual
160
2 Pull out the service cover horizontally away from the unit.
a Service cover screw
b Service cover
NOTICE
When closing the service cover, make sure that the tightening torque does NOT
exceed 1.4 (±0.2) N•m.
1 Remove the front grille.
2 Remove 1 screw from the electrical wiring box.
3 Open the electrical wiring box cover by pulling the protruding part on the top
of the cover.
4 Unhook the tabs on the bottom and remove the electrical wiring box cover.
a Screw
b Protruding part on the top of the cover
c Tab
Wall mounted indoor units
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Disconnect the power supply wiring from the power supply terminal X1M.
2 Remove the screw and power supply wiring bracket.
3 Pull the clip and remove the heat exchanger thermistor from its holder.
4 Remove the screw to disconnect the grounding wire from the heat exchanger.