Daikin Perfera RXM R Series Service Manual page 100

Split r32
Table of Contents

Advertisement

3
|
Components
To install the turbo fan assembly
Service manual
100
c Hook
d Screw (fan motor cover)
e Fan motor cover
f Wiring harness retainer
4 Route the DC fan motor wiring harness through the hooks and install the
harness retainer. Make sure the wiring harness is also routed through the
hooks located behind the harness retainer.
5 Lock the ferrite core on the DC fan motor wiring harness.
6 Install a new tie strap to fix the ferrite core to the indoor unit.
7 Install the turbo fan assembly, see
1 Install the turbo fan assembly on the DC fan motor assembly.
CAUTION
Do NOT install a damaged turbo fan assembly.
2 Install and tighten the nut to fix the turbo fan assembly.
a
b
a
a Screw (bellmouth)
b Bellmouth
c Nut (turbo fan assy)
d Turbo fan assy
3 Install the bellmouth in the correct location on the indoor unit. Install and
tighten the 4 screws to fix the bellmouth.
4 Slowly rotate the turbo fan and check that it does NOT touch the bellmouth.
Repair as needed.
5 Install the indoor unit heat exchanger on the 2 hooks on the right side.
"Repair
procedures" [
d
c
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
4
 96].
a
a
FVXM25~50A
Split New Perfera R32