Daikin Perfera RXM R Series Service Manual page 150

Split r32
Table of Contents

Advertisement

3
|
Components
To install the propeller fan blade assembly
Service manual
150
4 Attach the DC fan motor harness to the switch box.
5 Install a new tie strap to fix the DC fan motor harness to the switch box.
6 Connect the DC fan motor connector to the connector on the main PCB.
7 Lock the ferrite bead.
e
f
a Tie strap
b DC fan motor harness
c Switch box
d Fan motor bracket
e Screw
f DC man motor assy
8 Route the DC fan motor harness through the harness retainers (at the back of
the fan motor bracket) and bend the harness retainers to attach the DC fan
motor harness.
9 Attach the DC fan motor harness to the switch box.
10 Install a new tie strap to fix the DC fan motor harness to the switch box.
11 Connect the DC fan motor connector to the connector on the main PCB.
12 Install the propeller fan blade assembly, see
1 Install the propeller fan blade assembly on the DC fan motor assembly.
CAUTION
Do NOT install a damaged propeller fan blade assembly.
2 Install and tighten the nut to fix the propeller fan blade assembly.
c
d
e
a
a
b
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
b
4
"Repair
procedures" [
 148].
Split New Perfera R32
ESIE20-11 – 2021.01
FVXM25~50A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents